What this check does
DSALTA compares the users on the Aiven Access page against your People directory, matched by email within your organization. It passes when every Aiven user is an active employee on the People page.This check also runs on 115 other integrations — see User access to Critical System should be valid for the full list.
Passes when: Every user with Aiven access is an active employee on the People page.
Why this matters
Access to the organization’s managed data infrastructure must be limited to current, authorized employees.How to fix
Review Aiven organization users- Sign in to the Aiven Console as an organization admin.
- Open Admin → Users. Each row is one organization user.
- Compare every user against your current employee roster, paying attention to any address on an external domain.
- For anyone who should no longer have access, click Actions → Remove beside their entry and confirm. Aiven removes them from every group and project in the organization at the same time.
- If your organization signs users in through an identity provider, make the change in the identity provider instead — Aiven asks that IdP-managed users are added and removed there.
- In DSALTA, go to People and confirm every remaining Aiven user maps to an active employee.
Frequently asked questions
How often does this check run?
How often does this check run?
Once a day, at 02:00 America/New_York, while the integration is connected. A run is skipped entirely if the integration is not in a connected state, or if the test has been deactivated.To see a fix reflected sooner, open the test from Data Library → Tests and click Run in the Run Test row. You need Full Access to run a test on demand.
What does the status actually tell me?
What does the status actually tell me?
The Status column answers “did the check run?”, not “did I pass”. Completed means DSALTA reached your system and finished evaluating — a check that ran and found a problem is still Completed.To see what it found, open the test and read the result code on the Source Data tab. 200 means nothing to fix; 204 means the check did not apply to your environment; 207 means it ran and found a compliance gap you need to act on. See Understanding test results.
The check shows Failed. Does that mean I am non-compliant?
The check shows Failed. Does that mean I am non-compliant?
Usually not. On an integration-powered check, Failed means DSALTA was blocked and could not evaluate it — result code 403 (a missing permission) or 428 (a setting DSALTA still needs from you). Code 500 means the run failed on DSALTA’s side.A genuine compliance gap does not turn the list red — it runs to completion and shows 207.
What if this check does not apply to us?
What if this check does not apply to us?
Deactivate it: open the test from Data Library → Tests, then use the ⋮ menu at the top right of the panel and choose Deactivate Test. It applies immediately, with no confirmation step.Write your justification in the Comments tab before you deactivate. Once deactivated, every other tab is grayed out, so Comments is the only place an auditor can read why — see Test detail.
Does DSALTA change my configuration?
Does DSALTA change my configuration?
No. DSALTA only reads. It never creates, modifies, or deletes resources, and every remediation step is performed by your team directly in the third-party product.
.png?fit=max&auto=format&n=tsMQJyneJ1xquFUo&q=85&s=4d401cc03b547d99b6f75a6bd170c334)