Skip to main content

What this check does

DSALTA matches each user with active Sanity access to your People directory by email. If a matched person is offboarded (terminated or in offboarding) but still has active access, the check flags it as a serious issue.
This check also runs on 112 other integrations — see Offboarded users should not have active access for the full list.
Passes when: No offboarded employee retains active Sanity access.

Why this matters

Offboarded employees must not retain access to the organization’s content platform.

How to fix

Remove offboarded members from Sanity
  1. Open sanity.io/manage as a project Administrator.
  2. Select each project the person belongs to, open Members, and remove them.
  3. Open Settings → API → Tokens in each project and delete any token the person created — a project API token is not tied to a user and keeps working after they leave.
  4. In DSALTA, go to People and confirm each of those employees is marked terminated with an end date.
Once resolved, DSALTA records a 200 (compliant) result on this test’s Source Data tab at the next scheduled run.

Frequently asked questions

Once a day, at 02:00 America/New_York, while the integration is connected. A run is skipped entirely if the integration is not in a connected state, or if the test has been deactivated.To see a fix reflected sooner, open the test from Data Library → Tests and click Run in the Run Test row. You need Full Access to run a test on demand.
The Status column answers “did the check run?”, not “did I pass”. Completed means DSALTA reached your system and finished evaluating — a check that ran and found a problem is still Completed.To see what it found, open the test and read the result code on the Source Data tab. 200 means nothing to fix; 204 means the check did not apply to your environment; 207 means it ran and found a compliance gap you need to act on. See Understanding test results.
Usually not. On an integration-powered check, Failed means DSALTA was blocked and could not evaluate it — result code 403 (a missing permission) or 428 (a setting DSALTA still needs from you). Code 500 means the run failed on DSALTA’s side.A genuine compliance gap does not turn the list red — it runs to completion and shows 207.
Deactivate it: open the test from Data Library → Tests, then use the menu at the top right of the panel and choose Deactivate Test. It applies immediately, with no confirmation step.Write your justification in the Comments tab before you deactivate. Once deactivated, every other tab is grayed out, so Comments is the only place an auditor can read why — see Test detail.
No. DSALTA only reads. It never creates, modifies, or deletes resources, and every remediation step is performed by your team directly in the third-party product.