Skip to main content
Connect Infisical with a machine identity’s Client ID and Client Secret (Universal Auth) to sync organization members and projects, and run access reviews. Read-only.
Read-only access. DSALTA only reads data from this integration. It never creates, modifies, or deletes anything in your environment, and every remediation step is performed by your team directly in the third-party product.
What you’ll see. The Access page lists the members of the Infisical organization the machine identity belongs to, with their name, email and organization role, and respects Infisical’s own active flag — a member Infisical reports as inactive is shown as Inactive. Pending invitations are left out. Infisical reports no join date or MFA state on this endpoint, so the MFA column shows Unknown and each row is stamped with the date of the sync. Machine identities themselves are not listed.
DSALTA collects this integration’s data when you connect it — you can refresh it at any time with Sync from integrations on the Integrations page. The compliance checks below re-run once a day at 02:00 America/New_York.

What DSALTA reads

DSALTA reads the Infisical organization membership roster — names, emails, roles and active state — which appears on your Access page; and the organization’s projects, which appear on your Inventory page by name and slug. Secrets are never read.It calls these Infisical endpoints on app.infisical.com:
  • /api/v1/auth/universal-auth/login (exchanges the Client ID and Secret for an access token)
  • /api/v2/organizations/{orgId}/memberships
  • /api/v2/organizations/{orgId}/workspaces
Every request is a read. DSALTA has no code path that creates, modifies, or deletes anything in your Infisical environment. The organization is taken from the access token Infisical issues to the identity; there is nothing to select.

Troubleshooting

Each Universal Auth login consumes one use of the client secret. DSALTA caches the access token and re-logs in only when it expires, but a client secret created with a capped Max Number of Uses eventually returns Access denied due to client secret usage limit reached. Create a new client secret with Max Number of Uses set to 0 (unlimited), then disconnect and connect again. Note that disconnecting permanently deletes the data already collected from Infisical.
Wrong Client ID or Client Secret, a revoked secret, or an identity whose organization role cannot read members. Give the identity a role that can read members, create a fresh secret, and connect again.
Open Integrations in the DSALTA sidebar, stay on the Connected tab, and click Manage on the integration’s card. Open the Status tab: it shows either Connected and working properly or Connection issues detected.Use the Status tab, not Overview — Overview always reports Connected regardless of the real state.
On an integration-powered check, Failed normally means DSALTA was blocked rather than that you are non-compliant. Open the test, go to Source Data, and read the result code: 403 is a missing permission, 428 is a setting DSALTA still needs, 500 is a failure on DSALTA’s side.A real compliance gap shows 207 and leaves the test looking Completed. See Understanding Test Results.
Compliance checks re-run once a day at 02:00 America/New_York. To refresh sooner, open Integrations → Connected and click Sync from integrations at the top right — it refreshes every connected integration at once.
There is no Reconnect, Repair or Refresh Token button. The only repair available is to disconnect and connect again.
Disconnecting is destructive and cannot be undone. DSALTA removes the access records, inventory, vulnerabilities, code changes, incidents and device records collected from this integration, and deletes the test results tied to the connection. Export anything you still need as audit evidence first — see Integration errors.
That is expected. Configure scope is read-only — it shows what DSALTA is permitted to read, and has no Save action. To change what DSALTA can see, change the permissions on the credential in the third-party product, then disconnect and connect again.