What this check does

Retrieves account password policy and validates against requirements. Passes when: Password policy meets minimum length, complexity, and rotation requirements.

Why this matters

Strong password policies prevent brute-force and credential-stuffing attacks.

How to fix

Set the account password policy
  1. Sign in to the AWS Console and navigate to IAM → Account settings.
  2. Under Password policy, click Edit.
  3. Set Minimum password length to 14 and enable Require at least one uppercase letter, Require at least one lowercase letter, Require at least one number, and Require at least one non-alphanumeric character.
  4. Enable Password expiration (90 days, or per your policy) and set Password reuse prevention to remember the last 24 passwords.
  5. Click Save changes.
Or from the command line:
Once resolved, DSALTA records a 200 (compliant) result on this test’s Source Data tab at the next scheduled run.

Frequently asked questions

Once a day, at 02:00 America/New_York, while the integration is connected. A run is skipped entirely if the integration is not in a connected state, or if the test has been deactivated.To see a fix reflected sooner, open the test from Data Library → Tests and click Run in the Run Test row. You need Full Access to run a test on demand.
The Status column answers “did the check run?”, not “did I pass”. Completed means DSALTA reached your system and finished evaluating — a check that ran and found a problem is still Completed.To see what it found, open the test and read the result code on the Source Data tab. 200 means nothing to fix; 204 means the check did not apply to your environment; 207 means it ran and found a compliance gap you need to act on. See Understanding test results.
Usually not. On an integration-powered check, Failed means DSALTA was blocked and could not evaluate it — result code 403 (a missing permission) or 428 (a setting DSALTA still needs from you). Code 500 means the run failed on DSALTA’s side.A genuine compliance gap does not turn the list red — it runs to completion and shows 207.
Deactivate it: open the test from Data Library → Tests, then use the menu at the top right of the panel and choose Deactivate Test. It applies immediately, with no confirmation step.Write your justification in the Comments tab before you deactivate. Once deactivated, every other tab is grayed out, so Comments is the only place an auditor can read why — see Test detail.
No. DSALTA only reads. It never creates, modifies, or deletes resources, and every remediation step is performed by your team directly in the third-party product.